37 standard ranges, 100 SCCM to 1000 SLPM. Each row shows the full-scale range, process connection, pressure drop across the instrument and maximum operating pressure — the four figures that decide whether a unit fits your loop.
Laminar differential-pressure meters. The workhorse range for laboratory and pilot-plant flow measurement.
| Model | Type | Full-scale range | Process connection | Pressure drop (air to atmosphere) | Operating pressure |
|---|---|---|---|---|---|
| P-1000SLPM-D | Gas mass flow meter | 0 – 1000 SLPM | 3/4" NPT female | 6.0 PSID | 11.5 – 160 PSIA |
| P-100SCCM-D | Gas mass flow meter | 0 – 100 SCCM | 1/8" NPT female | 1.0 PSID | 11.5 – 160 PSIA |
| P-100SLPM-D | Gas mass flow meter | 0 – 100 SLPM | 1/4" NPT female | 2.5 PSID | 11.5 – 160 PSIA |
| P-10SLPM-D | Gas mass flow meter | 0 – 10 SLPM | 1/8" NPT female | 1.0 PSID | 11.5 – 160 PSIA |
| P-1SLPM-D | Gas mass flow meter | 0 – 1 SLPM | 1/8" NPT female | 1.0 PSID | 11.5 – 160 PSIA |
| P-200SLPM-D | Gas mass flow meter | 0 – 200 SLPM | — | — | 11.5 – 160 PSIA |
| P-20SLPM-D | Gas mass flow meter | 0 – 20 SLPM | 1/8" NPT female | 1.0 PSID | 11.5 – 160 PSIA |
| P-2SLPM-D | Gas mass flow meter | 0 – 2 SLPM | 1/8" NPT female | 1.0 PSID | 11.5 – 160 PSIA |
| P-500SCCM-D | Gas mass flow meter | 0 – 500 SCCM | 1/8" NPT female | 1.0 PSID | 11.5 – 160 PSIA |
| P-500SLPM-D | Gas mass flow meter | 0 – 500 SLPM | 3/4" NPT female | 4.0 PSID | 11.5 – 160 PSIA |
| P-50SLPM-D | Gas mass flow meter | 0 – 50 SLPM | 1/4" NPT female | 2.0 PSID | 11.5 – 160 PSIA |
| P-5SLPM-D | Gas mass flow meter | 0 – 5 SLPM | 1/8" NPT female | 1.0 PSID | 11.5 – 160 PSIA |
Integral closed-loop control valve. Setpoint via analog signal, serial or fieldbus.
| Model | Type | Full-scale range | Process connection | Pressure drop (air to atmosphere) | Operating pressure |
|---|---|---|---|---|---|
| PF-1000SLPM-D | Gas mass flow controller | 0 – 1000 SLPM | 3/4" NPT female | 14.0 PSID | 11.5 – 160 PSIA |
| PF-100SCCM-D | Gas mass flow controller | 0 – 100 SCCM | 1/8" NPT female | 1.0 PSID | 11.5 – 160 PSIA |
| PF-100SLPM-D | Gas mass flow controller | 0 – 100 SLPM | 1/4" NPT female | 15.5 PSID | 11.5 – 160 PSIA |
| PF-10SLPM-D | Gas mass flow controller | 0 – 10 SLPM | 1/8" NPT female | 5.5 PSID | 11.5 – 160 PSIA |
| PF-1SLPM-D | Gas mass flow controller | 0 – 1 SLPM | 1/8" NPT female | 1.5 PSID | 11.5 – 160 PSIA |
| PF-200SLPM-D | Gas mass flow controller | 0 – 200 SLPM | — | — | 11.5 – 160 PSIA |
| PF-20SLPM-D | Gas mass flow controller | 0 – 20 SLPM | 1/8" NPT female | 12.0 PSID | 11.5 – 160 PSIA |
| PF-2SLPM-D | Gas mass flow controller | 0 – 2 SLPM | 1/8" NPT female | 3.0 PSID | 11.5 – 160 PSIA |
| PF-500SCCM-D | Gas mass flow controller | 0 – 500 SCCM | 1/8" NPT female | 1.0 PSID | 11.5 – 160 PSIA |
| PF-500SLPM-D | Gas mass flow controller | 0 – 500 SLPM | 3/4" NPT female | 6.5 PSID | 11.5 – 160 PSIA |
| PF-5SLPM-D | Gas mass flow controller | 0 – 5 SLPM | 1/8" NPT female | 2.0 PSID | 11.5 – 160 PSIA |
Battery-powered field units for verification on installed lines.
| Model | Type | Full-scale range | Process connection | Pressure drop (air to atmosphere) | Operating pressure |
|---|---|---|---|---|---|
| PE-100SCCM-D | Portable gas mass flow meter | 0 – 100 SCCM | 1/8" NPT female (100 SCCM–20 SLPM) | 1.0 PSID | 11.5 – 160 PSIA |
| PE-100SLPM-D | Portable gas mass flow meter | 0 – 100 SLPM | 1/8" NPT female (100 SCCM–20 SLPM) | 2.5 PSID | 11.5 – 160 PSIA |
| PE-10SLPM-D | Portable gas mass flow meter | 0 – 10 SLPM | 1/8" NPT female (100 SCCM–20 SLPM) | 1.0 PSID | 11.5 – 160 PSIA |
| PE-1SLPM-D | Portable gas mass flow meter | 0 – 1 SLPM | 1/8" NPT female (100 SCCM–20 SLPM) | 1.0 PSID | 11.5 – 160 PSIA |
| PE-20SLPM-D | Portable gas mass flow meter | 0 – 20 SLPM | 1/8" NPT female (100 SCCM–20 SLPM) | 1.0 PSID | 11.5 – 160 PSIA |
| PE-500SCCM-D | Portable gas mass flow meter | 0 – 500 SCCM | 1/8" NPT female (100 SCCM–20 SLPM) | 1.0 PSID | 11.5 – 160 PSIA |
| PE-5SLPM-D | Portable gas mass flow meter | 0 – 5 SLPM | 1/8" NPT female (100 SCCM–20 SLPM) | 1.0 PSID | 11.5 – 160 PSIA |
For near-atmospheric processes where restriction matters. Maximum line pressure 60 PSIA.
| Model | Type | Full-scale range | Process connection | Pressure drop (air to atmosphere) | Operating pressure |
|---|---|---|---|---|---|
| PFZ-10SLPM-D | Low-pressure-drop gas mass flow controller | 0 – 10 SLPM | — | — | Max. 60 PSIA |
| PFZ-2SLPM-D | Low-pressure-drop gas mass flow controller | 0 – 2 SLPM | — | — | Max. 60 PSIA |
| PZ-5SLPM-D | Low-pressure-drop gas mass flow meter | 0 – 5 SLPM | — | — | Max. 60 PSIA |
Gas bottle, reactor and pilot-plant duty up to 320 PSIA.
| Model | Type | Full-scale range | Process connection | Pressure drop (air to atmosphere) | Operating pressure |
|---|---|---|---|---|---|
| PFT-50SLPM-D | High-pressure gas mass flow controller | 0 – 50 SLPM | — | — | 11.5 – 320 PSIA |
Upgraded wetted materials and seals for corrosive and reactive gases.
| Model | Type | Full-scale range | Process connection | Pressure drop (air to atmosphere) | Operating pressure |
|---|---|---|---|---|---|
| PFU-100SLPM-D | Corrosion-resistant gas mass flow controller | 0 – 100 SLPM | 1/4" NPT female | 2.5 PSID | 11.5 – 160 PSIA |
| PFU-250SLPM-D | Corrosion-resistant gas mass flow controller | 0 – 250 SLPM | 1/2" NPT female | 2.4 PSID | 11.5 – 160 PSIA |
| PFV-5SLPM-D | Corrosion-resistant gas mass flow controller | 0 – 5 SLPM | 1/8" NPT female | 2.0 PSID | 11.5 – 160 PSIA |
Tell us the gas, the flow you need to control or measure, and the pressures either side of the instrument. We will size it and quote it.
Request a quotation