PE series portable flow meters

PE-100SCCM-D
Portable gas mass flow meter — 0 – 100 SCCM

PE-100SCCM-D is a portable gas mass flow meter covering 0 – 100 SCCM, with 1/8" NPT female (100 SCCM–20 SLPM) process connections, 1.0 PSID pressure drop at full scale and an operating pressure range of 11.5 – 160 PSIA.

Request a quotation

Specification

ModelPE-100SCCM-D
TypePortable gas mass flow meter
Full-scale range0 – 100 SCCM
Process connection1/8" NPT female (100 SCCM–20 SLPM)
Pressure drop (air to atmosphere, full scale)1.0 PSID
Operating pressure11.5 – 160 PSIA

What this range covers

sub-litre-per-minute duty — chromatography carrier and sample gas, leak and seal testing, small-batch gas blending, and bench rigs where a few hundred standard cubic centimetres per minute is the whole measurement.

The published figure is 1.0 PSID measured with air exhausting to atmosphere at full scale. As a meter there is no control valve in the path; this is the restriction of the laminar element alone, and the upstream supply must hold at least this differential above downstream at full-scale flow.

As a rule of thumb, size the instrument so your working flow falls between roughly 30% and 90% of full scale — well above the bottom of the range, where resolution is poor, and below the top, where the pressure drop figure quoted here applies. Instrument calibration is gas-specific: tell us the gas you are metering and we will confirm whether the published range applies directly or needs a correction.

Before you order — three things to confirm

  1. The gas. Calibration follows the gas you name. Reactive, corrosive or gas-mixture duty may need different wetted materials and seals — tell us the composition.
  2. The pressures either side. The pressure-drop column is measured to atmosphere at full scale. If your downstream pressure is above atmosphere, the usable span shifts; give us upstream and downstream pressure and we will confirm whether PE-100SCCM-D still fits.
  3. The connection. This unit is supplied with 1/8" NPT female (100 SCCM–20 SLPM). Check your mating fitting and tube size before ordering — an adaptor changes both the dead volume and the effective restriction on low-range units.

Other models in the PE series portable flow meters

ModelTypeFull-scale rangeProcess connectionPressure dropOperating pressure
PE-100SLPM-DPortable gas mass flow meter0 – 100 SLPM1/8" NPT female (100 SCCM–20 SLPM)2.5 PSID11.5 – 160 PSIA
PE-10SLPM-DPortable gas mass flow meter0 – 10 SLPM1/8" NPT female (100 SCCM–20 SLPM)1.0 PSID11.5 – 160 PSIA
PE-1SLPM-DPortable gas mass flow meter0 – 1 SLPM1/8" NPT female (100 SCCM–20 SLPM)1.0 PSID11.5 – 160 PSIA
PE-20SLPM-DPortable gas mass flow meter0 – 20 SLPM1/8" NPT female (100 SCCM–20 SLPM)1.0 PSID11.5 – 160 PSIA
PE-500SCCM-DPortable gas mass flow meter0 – 500 SCCM1/8" NPT female (100 SCCM–20 SLPM)1.0 PSID11.5 – 160 PSIA
PE-5SLPM-DPortable gas mass flow meter0 – 5 SLPM1/8" NPT female (100 SCCM–20 SLPM)1.0 PSID11.5 – 160 PSIA

See the full PE series portable flow meters table or compare all 37 ranges.