DONGDE YUNHAI Alicat Flow Instrument Specialists
Alicat Mass Flow Instruments

Mass flow meters and controllers,
sourced and exported from China.

We supply Alicat gas mass flow instruments to universities, research institutes, OEM integrators and industrial end users worldwide — with engineering selection support, fast quotation and export-ready documentation. 37 standard ranges from 100 SCCM to 1000 SLPM, in stock or on short lead time.

37Standard ranges listed
0.6%Accuracy of reading
98Preloaded gases
24 hQuotation turnaround

Product lines we supply

Gas mass flow meters and controllers in the Alicat M and MC series equivalents, plus the portable, low-pressure-drop, high-pressure and corrosion-resistant variants.

P SERIES

Gas mass flow meters

Laminar differential-pressure measurement, 100 SCCM to 1000 SLPM. Reads mass flow, volumetric flow, pressure and temperature on the same screen.

View all 12 models →
PF SERIES

Gas mass flow controllers

Closed-loop control with an integrated proportional valve. 1 SCCM to 1000 SLPM, response in the millisecond range, no warm-up drift.

View all 11 models →
PE SERIES

Portable flow meters

Battery-powered field units for verification and troubleshooting on installed lines, with the same measurement core as the bench instruments.

View all 7 models →
PZ / PFZ

Low-pressure-drop

For atmospheric and near-atmospheric processes where a standard meter would introduce too much restriction — maximum 60 PSIA line pressure.

View all 3 models →
PFT

High-pressure controllers

Up to 320 PSIA operating pressure for gas bottle, reactor and pilot-plant duty.

View all 1 models →
PFU / PFV

Corrosion-resistant

For corrosive and reactive gases, with upgraded wetted materials and seals. Up to 250 SLPM full scale.

View all 3 models →

Why buyers work with us

Instruments are widely available. What is scarce is a supplier who can answer a specification question the same day and ship with the paperwork already in order.

01

Selection support

Send the gas, flow range, upstream and downstream pressure, and we will confirm whether the instrument will actually work in your loop — including the pressure drop across the meter, which is where most sizing errors happen.

02

Stock and lead time

Common ranges are held in stock. For non-stock items we quote a realistic lead time rather than an optimistic one, and we tell you when a range is not available.

03

Export documentation

Commercial invoice, packing list, certificate of origin and NIST-traceable calibration certificate, prepared to match your customs entry. HS code and declared value agreed before dispatch.

Typical specifications

Figures below apply to the standard P and PF series. Exact values are confirmed per model on the quotation — always check before specifying into a system.

Measurement principle
Laminar differential pressure
Accuracy
±0.6% of reading or ±0.1% of full scale, whichever is greater
Repeatability
±(0.1% of reading + 0.02% of full scale)
Turndown
10,000:1 (0.01% to 100% of full scale)
Operating pressure
11.5 – 160 PSIA (standard); 320 PSIA (high-pressure version)
Gases
98 preloaded gases (Gas Select), user-defined mixtures supported
Wetted materials
302/303/304/316L stainless steel, FKM, alumina ceramic, brass, glass, gold
Process connection
1/8" to 3/4" NPT female, depending on range
Digital output
RS-232 / RS-485 with Modbus RTU
Optional protocols
Modbus TCP/IP, EtherCAT, EtherNet/IP, PROFINET, PROFIBUS, IO-Link
Analog output
4–20 mA, 0–5 V, 1–5 V or 0–10 V (option)
Supply
12–24 Vdc, 250 mA (290 mA with 4–20 mA output)
Display
Monochrome LCD or colour TFT touchscreen
Operating temperature
−10 to +60 °C
Ingress protection
IP40
Mounting orientation
Any position
Calibration
NIST-traceable certificate supplied with each instrument
Warranty
Limited lifetime, maintained by annual calibration

Applications

Where these instruments are most often specified.

University laboratories

Flow control in test rigs, reactors and analytical lines.

Bioprocess

Air, O₂, CO₂ and N₂ control for fermenters and cell culture.

Fuel cell testing

H₂ and air mass flow control at low pressure drop.

Semiconductor

Inert gas delivery, purge and carrier gas measurement.

Gas chromatography

Carrier and make-up gas control with stable low flows.

Leak testing

Mass flow measurement of leakage on pressure-decay rigs.

OEM integration

Panel-mounted controllers with serial or fieldbus output.

Calibration benches

Reference measurement for flow calibration stands.

Send us your operating conditions

Gas, flow range, upstream and downstream pressure, process connection and ambient conditions. We will come back with the correct model, the pressure drop it introduces, and a quotation.

Request a quotation