PF-100SCCM-D is a gas mass flow controller covering 0 – 100 SCCM, with 1/8" NPT female process connections, 1.0 PSID pressure drop at full scale and an operating pressure range of 11.5 – 160 PSIA.
Request a quotation| Model | PF-100SCCM-D |
|---|---|
| Type | Gas mass flow controller |
| Full-scale range | 0 – 100 SCCM |
| Process connection | 1/8" NPT female |
| Pressure drop (air to atmosphere, full scale) | 1.0 PSID |
| Operating pressure | 11.5 – 160 PSIA |
sub-litre-per-minute duty — chromatography carrier and sample gas, leak and seal testing, small-batch gas blending, and bench rigs where a few hundred standard cubic centimetres per minute is the whole measurement.
The published figure is 1.0 PSID measured with air exhausting to atmosphere at full scale. As a controller this figure includes the integral control valve, so the upstream supply must hold at least this differential above downstream at full-scale flow.
As a rule of thumb, size the instrument so your working flow falls between roughly 30% and 90% of full scale — well above the bottom of the range, where resolution is poor, and below the top, where the pressure drop figure quoted here applies. Instrument calibration is gas-specific: tell us the gas you are metering and we will confirm whether the published range applies directly or needs a correction.
| Model | Type | Full-scale range | Process connection | Pressure drop | Operating pressure |
|---|---|---|---|---|---|
| PF-1000SLPM-D | Gas mass flow controller | 0 – 1000 SLPM | 3/4" NPT female | 14.0 PSID | 11.5 – 160 PSIA |
| PF-100SLPM-D | Gas mass flow controller | 0 – 100 SLPM | 1/4" NPT female | 15.5 PSID | 11.5 – 160 PSIA |
| PF-10SLPM-D | Gas mass flow controller | 0 – 10 SLPM | 1/8" NPT female | 5.5 PSID | 11.5 – 160 PSIA |
| PF-1SLPM-D | Gas mass flow controller | 0 – 1 SLPM | 1/8" NPT female | 1.5 PSID | 11.5 – 160 PSIA |
| PF-200SLPM-D | Gas mass flow controller | 0 – 200 SLPM | — | — | 11.5 – 160 PSIA |
| PF-20SLPM-D | Gas mass flow controller | 0 – 20 SLPM | 1/8" NPT female | 12.0 PSID | 11.5 – 160 PSIA |
| PF-2SLPM-D | Gas mass flow controller | 0 – 2 SLPM | 1/8" NPT female | 3.0 PSID | 11.5 – 160 PSIA |
| PF-500SCCM-D | Gas mass flow controller | 0 – 500 SCCM | 1/8" NPT female | 1.0 PSID | 11.5 – 160 PSIA |
| PF-500SLPM-D | Gas mass flow controller | 0 – 500 SLPM | 3/4" NPT female | 6.5 PSID | 11.5 – 160 PSIA |
| PF-5SLPM-D | Gas mass flow controller | 0 – 5 SLPM | 1/8" NPT female | 2.0 PSID | 11.5 – 160 PSIA |
See the full PF series gas mass flow controllers table or compare all 37 ranges.
Send the gas, the flow you need to measure or control, and the pressures either side of the instrument. We will confirm the range and quote it — normally the same working day.
Request a quotation